718203-B21 for HP Lpe1605 16GB HBA for Bladesystem C-Class
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Guangdong
-
Validity to:
Long-term effective
-
Last update:
2017-11-28 02:50
-
Browse the number:
299
Company Profile
HSDA Technology Co., LimitedBy certification [File Integrity]
Contact:Mr. Louis Yu(Mr.)
Email:
Telephone:
Phone:
Area:Guangdong
Address:Guangdong
Website: http://it-hsda.beitools.com/
Product Details
718203-B21 for HP Lpe1605 16GB HBA for Bladesystem C-Class
Technical Specifications
System Unit Dimensions (H x W) 3.5 in x 3.9 in
Media N/A (Always connects to BladeSystem interconnect module)
Ports Two
System Inlet Temperature
Operating
10° to 70°C (55° to 158°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity (non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, noncondensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, noncondensing.
Altitude Operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Power Consumption
Max 11.3 W
718203-B21 for HP Lpe1605 16GB HBA for Bladesystem C-Class
Technical Specifications
System Unit Dimensions (H x W) 3.5 in x 3.9 in
Media N/A (Always connects to BladeSystem interconnect module)
Ports Two
System Inlet Temperature
Operating
10° to 70°C (55° to 158°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity (non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, noncondensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, noncondensing.
Altitude Operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Power Consumption
Max 11.3 W
718203-B21 for HP Lpe1605 16GB HBA for Bladesystem C-Class